This unit was installed in 2015. It has been operated successfull for about 2 years.
The following are specific information about this project.
Hydro turbine Generator Unit Model Selection
Project Data | ||||||||||||||||
Design Head | 142m | Max. head | Min. head | 1.8m³/s | ||||||||||||
Design flow | 0.9m³/s | Max. flow | Min. flow | |||||||||||||
Install Capacity | 900kw | Installed sets | 2 | Rated voltage | 400V | |||||||||||
Specification | ||||||||||||||||
Turbine | Generator | |||||||||||||||
Model | XJA-W-63/1*15 | Model | SFW900-6/1180 | |||||||||||||
Structure | Pelton | Rated voltage | 400V | Rated current | 103.1A | |||||||||||
Blade angle | Rated capacity | 900kw | Rated RPM | 1000r/min | ||||||||||||
Efficiency | 83% | Exciting voltage | 39V | Exciting current | 275A | |||||||||||
Runner material | Cast Steel | Insulation Grade | F/F | Efficiency | 93.5% | |||||||||||
Gross Weight | 7.2T | Power Factor | 0.8(Lag) | Rated Frequency | 50Hz | |||||||||||
Heaviest piece | Gross Weight | 10T | Heaviest piece | 3T | ||||||||||||
L×W×H | L×W×H | |||||||||||||||
Excitation Unit | Governing Device | |||||||||||||||
Model | Model | BKSF | ||||||||||||||
Unit Quotation | ||||||||||||||||
# | Item | Model | Qty. | Unit Price(US$) | Amount (US$) | |||||||||||
1 | Turbine | XJA-W-63/1*15 | 1 | |||||||||||||
2 | Generator | SFW900-6/990 | 1 | |||||||||||||
3 | Manual and electric Speed governor | DST-300 | 1 | |||||||||||||
4 | Control panel | BKSF(2in1) | 1 | |||||||||||||
5 | Main valve | Z41H-2.5 DN=600 | 1 |